DU10MbRetry

D = Device(MODBUS)

U = Utility functions

The DU10MbRetry function manages the execution of the SEND command to the MODBUS device and check the success of the command admitting a series of programmed in the event that the data is altered during transmission.

DU10MbRetry (Modbus, MaxAttempt, RelaxTime, Attempt, Result)

Parameters:

IN/OUTVARIABLE TYPEEEXAMPLE NAMEDIM
IN INTDEVICE Modbus - Mnemonic name of MODBUS devices used
IN SYSTEM o GLOBAL o
CONST
MaxAttempt B Maximum number of retries. Setting 0 the command must be satisfied on the first try.
IN GLOBAL o
CONST
RelaxTime L Indicates the time between an attempt and the subsequent. With zero there is no time.
OUT GLOBAL Attempt B Returns the value of the retries.
OUT GLOBAL Result B Result of the operation:
0 = a successful command (in Attempt to evaluate possibly if they were attempts).
1 = exit for reasons too many attempts.
2 = exit for incorrect value of err parameter (other than 6, 51, 52, 53,54 or 55).
3 = exit for incorrect value of parameters (Maxattemp < 0 or tout parameter to zero. \\

Note

The attempts are executed only if the parameter err parameter takes the 6, 51, 52, 53,54 or 55 values.
Is never evaluated serr parameter.