Function name CTUD_010
Function version 1.0
Function state stable
Compatibility with IEC61131-3 compatible

Graphic symbol :

Input / Output :

Name Belonging Group Access Types of data Description
EN Left Power Flow IEC1131-3 enable input
CU Normal R , RW F , B , W , L , S Count up input
CD Normal R , RW F , B , W , L , S Count down input
R Normal R , RW F , B , W , L , S Reset counter
LD Normal R , RW F , B , W , L , S Load counter
PV Normal R , RW B , W , L , S Preset counter
QU Normal W , RW F , B , W , L , S Status counter Up
QD Normal W , RW F , B , W , L , S Status counter Down
CV Normal W , RW B , W , L , S Counter current value
ENO Right Power Flow IEC1131-3 enable output

Description :

The function block Up/Down Counter counts forward or backward from the preset value on the raising front of the count up input (CU) or of the count down input (CD). When the current counter value (CV) is equal to the one preset, the output (QU) is activated. When the current counter value (CV) is equal to zero, the output (QD) is activated. The counter loads the current counter value (CV) with the preset value (PV) when the load input (LD) is activated. At the same time, the counter resets and loads the counter current value (CV) with zero when reset (R) is active and it stops counting when it reaches the preset value of zero.