AN016 - Battery replacement procedure
Before replacing the battery we recommend that you verify that the battery is new:
-
charge (use the tester);
-
compatibility.
For greater security and data protection, make a copy of the data in RAM with the Project procedure > Backup or with the Project procedure > Savedata with the Qview software.
The battery replacement must be provided with the equipment turned on.
Replacement descriptions:
Fig.1 Remove the battery cover with flat screwdriver to pry the tabs |
Fig.2 Replace the battery make sure of respect the polarity |
Fig.3 Put back the cover battery |
Fig.4 Turn off and than turn on the instrument |
Fig.5 If the procedure is correct BATT led stay OFF 1) |
If after replacing the battery the BATT stays on or flashes you should contact the constructor of the machine.
If the BATT led turn OFF, but the ERR led flash for Error Checksum, you should restore the data save with the Project procedure > Restore or Project > Recalldata from Qview.
If you ran a Project > Backup is possible to run the Restore even without the PC.
If after the installation or battery replacement, HALT led flash, set the data, the time and reset the “Internal Error“.
(Note: if the command does not work, turn off the instrument, turn on the instrument and repeat the procedure)